- KETT
The LZ-200J is a portable coating thickness tester equipped with electromagnetic and eddy-current testing methods and an internal printer. This unit can quickly and easily handle coating thickness measurements of various types of coatings on iron and steel of non-ferrous substrates. Plus, this unit is equipped with many valuable functions such as calibration, memory, limit setup, and a statisticalcalculation function that, at the press of a button, allows you to find the average
value, standard deviation, and largest and smallest values measured.
Specifications | LZ-200J |
---|---|
Measurement method | Electromagnetic induction/Eddy-current |
Applications | Non-magnetic coating on iron and steel (ferrous) substrates and Insulating coatings on non-ferrous substrates. |
Measurement range | Electromagnetic: 0-1500μm or 60.00mils Eddy-current: 0-800μm or 32.00mils |
Measurement precision | Electromagnetic : Under 15μm ±0.3mm, 15μm or greater ±2% Eddy-current : Under 50μm: ±1μm, 50μm or greater: ±3% |
Resolution | 0.1μm (less than 100μm), 1.0μm (100μm or greater) |
Statistical functions | Number of measurements, Average value, Standard deviation, Maximum value, Minimum value, Block numbers. |
Probe | One-point contact fixed pressure (LEP-J, LHP-J) |
Display format | Digital (LCD, smallest displayed unit 0.1mm) |
Output | RS-232C interface (transmission speed-2400bps) |
Power source | AC100V/220V (50/60Hz) or 1.5 (“AA” size Alkaline batteries) x 6 (main unit), Printer (“AA” size Alkaline batteries) x 4 |
Dimensions & Weight | 120(W)x250(D)x55(H)mm, 1.0kg / Shipment 2.5kg |
Accessories | Calibration Plate, Iron Substrate, Aluminium Substrate, Batteries (1.5V, “AA” Size Alkaline), Probe Adapter, AC Adapter, Printer Paper, Carrying Case |
Options | Data Management Software “McWave Series” and “MultiProp” (McWave Series and MultiProp are products of CEC Co.) |