Peacock Contact Point for Pic Test Code : XP1A-3, XP1A-2, XP1A-2R, XP1A-1, XP1A-08, XP1A-05, XP1B-3, XP1B-2, XP1B-2R, XP1B-1, XP1B-08, XP1B-05, XP1L-3, XP1L-2, XP1L-2R, XP1L-1, XP1L-08, XP1L-05, XP2-3, XP2-2, XP2-2R, XP2-1, XP2-08, XP2-05, XN1A-3, XN1A-2, XN1A-2R, XN1A-1, XN1A-08, XN1A-05

Peacock Contact Point for Pic Test

Code : XP1A-3, XP1A-2, XP1A-2R, XP1A-1, XP1A-08, XP1A-05, XP1B-3, XP1B-2, XP1B-2R, XP1B-1, XP1B-08, XP1B-05, XP1L-3, XP1L-2, XP1L-2R, XP1L-1, XP1L-08, XP1L-05, XP2-3, XP2-2, XP2-2R, XP2-1, XP2-08, XP2-05, XN1A-3, XN1A-2, XN1A-2R, XN1A-1, XN1A-08, XN1A-05

Lever Type Dial Indicators Accessories
Lever Type Dial Indicators Accessories

 

Replaceable contact point (carbide ball)
Replaceable contact point (carbide ball) Dimensions ; Contact Point

Contact points with 2mm dia, super-hard are attached to all
Pic-Test and New Pic-Test indicators, 1.0mm, 0.8mm and
0.5mm dia, contact points are also stock items.
Sø2.0 dia, Ruby ball is also available

 

For Pic Test (Change lever type)
Part No. ø ball (mm) L (mm) ød (mm) Applicable Indicator
XP1A-3 3 18.2 2.5 PC-1A, PC-1AE, PC-3
XP1A-2 2
XP1A-2R (ruby ball) 2
XP1A-1 1
XP1A-08 0.8
XP1A-05 0.5
XP1B-3 3 19.24 2.5 PC-1B, PC-1BE, PC-1BW
XP1B-2 2
XP1B-2R (ruby ball) 2
XP1B-1 1
XP1B-08 0.8
XP1B-05 0.5
XP1L-3 3 39.72 3.0 PC-1L, PC-1LE
XP1L-2 2
XP1L-2R (ruby ball) 2
XP1L-1 1
XP1L-08 0.8
XP1L-05 0.5
XP2-3 3 8.80 2.2 PC-2, PC-4
XP2-2 2
XP2-2R (ruby ball) 2
XP2-1 1
XP2-08 0.8
XP2-05 0.5

 

For New Pic Test (Without change lever type)
Part No. ø ball (mm) L (mm) ød (mm) Applicable Indicator
XN1A-3 3 17.74 2.5 PCN-1A, PCN-0, PCN-1AE, PCN-1AD, PCN-5, PCN-7A, PCN-1AU, PCN-5U
XN1A-2 2 PCN-1A, PCN-0, PCN-1AE, PCN-1AD, PCN-5, PCN-7A
XN1A-2R
(ruby ball)
2 PCN-1A, PCN-0, PCN-1AE, PCN-1AD, PCN-5, PCN-7A, PCN-1AU, PCN-5U
XN1A-1 1
XN1A-08 0.8
XN1A-05 0.5
XN1B-3 3 18.63 2.5 PCN-1B, PCN-1BE, PCN-1BU, PCN-1BZ(A), PCN-1BZ(B)
XN1B-2 2 PCN-1B, PCN-1BE, PCN-1BZ(A), PCN-1BZ(B)
XN1B-2R
(ruby ball)
2 PCN-1B, PCN-1BE, PCN-1BU, PCN-1BZ(A), PCN-1BZ(B)
XN1B-1 1
XN1B-08 0.8
XN1B-05 0.5
XN1L-3 3 39.00 2.5 PCN-1L, PCN-1LE, PCN-1LD, PCN-1LU, PCN-1LZ(A), PCN-1LZ(B)
XN1L-2 2 PCN-1L, PCN-1LE, PCN-1LD, PCN-1LZ(A), PCN-1LZ(B)
XN1L-2R
(ruby ball)
2 PCN-1L, PCN-1LE, PCN-1LD, PCN-1LU, PCN-1LZ(A), PCN-1LZ(B)
XN1L-1 1
XN1L-08 0.8
XN1L-05 0.5
XN2-3 3 14.18 2.2 PCN-2, PCN-2E, PCN-6, PCN-2U, PCN-6U, PCN-2Z(A), PCN-2Z(B)
XN2-2 2 PCN-2, PCN-2E, PCN-6, PCN-2Z(A), PCN-2Z(B)
XN2-2R
(ruby ball)
2 PCN-2, PCN-2E, PCN-6, PCN-2U, PCN-6U, PCN-2Z(A), PCN-2Z(B)
XN2-1 1
XN2-08 0.8
XN2-05 0.5
XN2B-3 3 13.00 2.2 PCN-2B, PCN-2BD, PCN-7C, PCN-SD, PCN-2BU
XN2B-2 2 PCN-2B, PCN-2BD, PCN-7C, PCN-SD
XN2B-2R
(ruby ball)
2 PCN-2B, PCN-2BD, PCN-7C, PCN-SD, PCN-2BU
XN2B-1 1
XN2B-08 0.8
XN2B-05 0.5
XNS-3 3 8.13 2.2 PCN-S, PCN-SU
XNS-2 2 PCN-S
XNS-2R
(ruby ball)
2 PCN-S, PCN-SU
XNS-1 1
XNS-08 0.8
XNS-05 0.5

 

Pic test holder
PTH-1/PTH-2/PTH-0
PTH-0 (Head only)
Dimensions ; PTH-1/PTH-2

PTH-1, PTH-2 ; ( ) PTH-2

Universal holder
PTH-3/PTH-4 Dimensions ; PTH-3/PTH-4

PTH-3, PTH-4 ; ( ) PTH-4

 

Centricator (Pic Test Indicators supplied on request)
PCD-2 Dimensions ; PCD-2
PCD-2
PCD-3/PCD-4 Dimensions ; PCD-3/PCD-4

PCD-3, PCD-4 ; ( ) PCD-4

Dovetail stem
DS-4/DS-6/DS-8

 

Right Angle Contact Point for PIC TEST ( XP1LX-2 )
Unique Contact Point not existing before!

Part No. XP1LX-2 PAT. No. 3065810
A Contact Point end bent at a right has made it possible to make a measurement of an object that
used to be impossible to measure!
Set the Contact Point so that it is horizontal and perpendicular to work.
Contact Point No. XP1LX-2

The Contact Point enable a measurement of a recessed
portion located at the back of a project portion that would
not be possible by the use of an existing Contact Point.
To use a Contact Point end bent at a right angle XP1LX-2
has made it possible to make a measurement of an object
that used to be impossible to measure!
Note) Dimension of Contact Point is for PC-1L.
( Dial Test Indicator )
Picture: Model No. PC-1L
with Contact Point XP1LX-2
PC-1L ( with Contact Point XP1LX-2 )

Also makes it possible to measure the
parallelism and run-out of grooves on
diffrent levels.
Dimension ( Contact Point XP1LX-2 )
Dimension ( Contact Point XP1LX-2 )